메뉴 바로가기 본문 바로가기

Articles

Introducing Multi-Stage Pilot Scale Rotary Kiln / SH-FU-267RKG5000

November 03, 2026

Equipment Introduction


This is a Multi-Stage Pilot-Scale Rotary Kiln featuring four independent tube furnaces arranged in a single line. 

It is equipped with an Alloy 601 tube (O.D. Ø267 × 6,180 mm), a maximum operating temperature of 800°C, and a total of 12 heating zones, enabling stage-by-stage thermal treatment with controlled temperature gradients in a continuous process.

 

The tube is approximately twice as long as that of the previous Pilot Plant Scale Rotary Kiln (Ø267 × 3,140 mm). 

This extended length allows for the validation of residence time and heating profiles under conditions closely resembling actual production processes before designing full-scale production equipment.

 

  

Key Features: Multi-Stage Independent Furnace Design with Adjustable Gaps


Instead of using a single long furnace, four independent furnaces are arranged with adjustable gaps between them. Each furnace can be moved horizontally, allowing the spacing between furnaces to be adjusted according to the temperature gradient requirements of the process.

 

Furnace Arrangement and Gap Adjustment


Each furnace is mounted on rails and can be moved horizontally, allowing the gaps between adjacent furnaces to be adjusted. Cooling fans beneath the exposed tube sections minimize thermal interference between stages.

  

Why Use a Separated Furnace Design?

 

In laboratory-scale processes, samples are typically placed in a tube furnace and subjected to stepwise heat treatment at temperatures such as 200°C → 400°C → 600°C.

In a single continuous furnace, heat transfer between adjacent heating zones makes it difficult to maintain such distinct temperature profiles. 

 

By physically separating the furnaces and incorporating air-cooling gaps between them, each stage can maintain its temperature independently. This allows laboratory-scale stepwise heat treatment conditions to be replicated in a continuous process.

 

  • Independent Temperature Control for Each Stage — Each heating zone is individually controlled using a total of 12 programmable temperature controllers and 12 K-type thermocouples.


  • Adjustable Gaps — The length of the unheated sections between furnaces can be adjusted to control the temperature gradient and residence time between stages.


  • Easy Tube Replacement — The furnaces feature an openable top-cover design, allowing convenient access for tube replacement.

 



 

 Specification 

 

 

ParameterSpecification 
Max Temperature800℃
Tube Material & DimensionAlloy 601 Seamless, O.D 267Ø / I.D 258Ø × 6,180mm (L)
Tube Tilt & Rotation SpeedTilt 0-3º, Rotation 0-5 rpm
No.1 Furnace 450 mm × 1 zone (total 450 mm)
No.2 Furnace450 mm × 2 zone (Incl. 25 mm support, total 925 mm)
No.3 Furnace450 mm × 8 zone (Incl. 25 mm × 7 support, total 3,775 mm)
No.4 Furnace300mm × 1 zone (total 300mm)
Temp. Controller & SensorProgram Controller 12 ea / K-type Sensor 12 ea
Feeding Vessel1st 10L + 2nd 10L, Pneumatic Butterfly Valve (200A)
Receiving Vessel1st 10L + 2nd 10L, Pneumatic Butterfly Valve (200A)
Gas In/Out & ExhaustGas Port 1/4" Tube Lock / Exhaust Port KF50
External Dimension7,872 W × 676 D × 2,400 H (mm)
Power Supply380V, 3P 4 Wire, 44kW

 

 




 

From left to right, the system consists of a Screw Feeder → Pre-Heating & Drying Zone → 2-Zone Heating Section → 8-Zone Heating Section → Post-Heating Zone → Discharge Section (Exhaust Port, View Port, and Heating Jacket).

 

The secondary receiving vessel is equipped with a cooling coil and chiller to cool the heat-treated material.

 

 

Feeding Section

 

The feeding section is equipped with two 10 L feeding vessels arranged in series and pneumatically actuated butterfly valves, enabling continuous material feeding without disrupting the controlled atmosphere inside the system.

 


 

Receiving Section


The receiving chamber features a KF50 exhaust port on the top and a view port at the rear. Two 10 L receiving vessels arranged in series and two pneumatically actuated valves are installed beneath the chamber, allowing heat-treated materials to be collected during operation without interrupting the process.

 


 

Applications


This system is ideal for pilot-scale process validation prior to full-scale production of powders and granules requiring stepwise temperature gradients, including drying, dehydration and decomposition, and calcination.

 

  • Lithium-Ion Battery Materials and Recycling — Cathode precursor calcination, anode material carbonization, and spent battery recycling


  • Catalyst and Activated Carbon Production — Manufacturing and regeneration of catalysts and activated carbon


  • Biomass Pyrolysis — Production of biochar and bio-oil


  • Ceramics and Advanced Materials — Calcination and thermal treatment of ceramic and advanced materials


  • Cement, Lime, and Inorganic Materials — Process modeling of high-temperature calcination


This system is custom-to-order. The number of furnaces, heating zone configuration, tube material, and tube length can be customized to meet specific process requirements.

 

Planning to scale up your thermal process? 

Share your material, target temperature profile, and required throughput, and our team will propose a configuration tailored to your process.

Contact: martin@samheung21.com I jay@samheung21.com

______________________________________________________________________________________________________________________________________

 

Written by Jay Bang, Bioengineer, SH Scientific 

 

 

 

 

 

 

 

 

Screenshot 2026-11-09 at 12Download

Screenshot 2026-11-03 at 3Download